Model | GL-T11R |
Applicable model | GL-R Series |
Relay output | FSD1,2 | 250 VAC 6 A 30 VDC 6 A (Resistance load) 240 VAC 2 A (COSø=0.3) (Inductive load) 24 VDC 1 A (COSø=0.3) (Inductive load) |
Life-span | Electrical life-span 2005 acura rl owner's manual download. | 100,000 cycles or more with 250 VAC 6 A resistance load (open/close frequency: 20 times/minute) 100,000 cycles or more with 30 VDC 6 A resistance load (open/close frequency: 20 times/minute) 500,000 cycles or more with 250 VAC 1 A resistance load (open/close frequency: 30 times/minute) 500,000 cycles or more with 30 VDC 1 A resistance load (open/close frequency: 30 times/minute) AC15: 100,000 cycles or more with 240 VAC 2 A inductive load (open/close frequency: 20 times/minute, cosø = 0.3) DC13: 100,000 cycles or more with 24 VDC 1 A inductive load (open/close frequency: 20 times/minute, L/R = 48 ms) |
Response time | ON→OFF | GL-R +10 ms |
OFF→ON | GL-R +32 ms |
Supplemental output (Non-safety-related output) | AUX | Transistor output (PNP/NPN input device can be connected.)*1 50 mA max., residual voltage 2.5 V max. (When the cable between the GL-R and GL-T11R is 5 m) |
Error output |
Muting lamp output | Incandescent lamp (24 VDC, 1 to 5.5 W) LED lamp (load current: 10 to 230 mA) can be connected. |
External input | EDM inputWait inputReset inputMuting input 1, 2Override input | ON voltage: [Power supply voltage - 5 V] to [Power supply voltage] OFF voltage: Open or 0 to 3 V Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only) |
Rating | Power voltage | 24 VDC ±10%, ripple (P-P) 10% or less, Class 2 |
Current consumption | 100 mA max. (24 VDC, GL-T11R only) |
Approved standards | EMC | EMS | EN61496-1, UL61496-1, IEC61496-1 |
EMI | EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
Safety | EN61496-1, UL61496-1, IEC61496-1 (Type4 ESPE) EN ISO13849-1 : 2015 (Category4, PLe) UL508, EN50178 |
Environmental resistance | Enclosure rating | IP20 (IEC60529) Must be installed within a control panel rated at IP54 or higher. |
Pollution degree | 2 |
Overvoltage category | III |
Operating ambient temperature | -10 to +55 °C (No freezing) |
Storage temperature | -25 to +60 °C (No freezing) |
Operating relative humidity | 15 to 85 % RH (No condensation) |
Storage relative humidity | 15 to 95 % RH |
Altitude | 2,000 m or less |
Vibration resistance | 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions |
Shock resistance | 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
Material | Main unit case | Polycarbonate |
Weight | Approx. 310 g |
*1 The output operation is the same as that when the PNP output type cable is used. |
E GL-R-IM
View and Download Keyence BL-500 Series user manual online. BL-500 Series Laser Bar code Reader. BL-500 Series Barcode Reader pdf manual download. Also for: Bl-501, Bl-500h, Bl-501h, Bl-550, Bl-551, Bl-550h, Bl-551h. Get KEYENCE GL-R Series Owner manual. Get all KEYENCE manuals! Sign up to create an account Facebook Twitter. By clicking Create Account, you agree to the Company’s. Connect all cables to the GL-R before installing the mounting brac ket to the GL-R unit. . KEYENCE no puede garantizar el funcionamiento o el rendimiento de la SL-R11 si se utiliza de modo diferente del estipulado en las especificaciones del presente manual de instrucciones o si se modifica la SL-R11. KEYENCE UK provides GL-R series; What makes a light curtain 'robust'? KEYENCE has designed a light curtain with a structure that prevents damage from parts or tools by narrowing the exposed lens area and recessing it in an impact resistant housing.
Center indicator
Dimensions
GL-RF
GL-RH
GL-RL
NOTICE
If the length for a single GL-R unit is 1280 mm or greater, use the following antivibration
mounting bracket additionally as an intermediate support bracket. The antivibration
mounting bracket must be selected according to the mounting bracket and installed on the
center of the GL-R unit indicated as position 'G'.
Beam axes
B: Detection heightC: Protection heightD: Beam axis pitch
GL-R23F23240220244
120
GL-R39F39400380404200
GL-R55F55560540564280
GL-R71F71720700724360
GL-R87F87880860884440
GL-R103F103104010201044520
GL-R119F119120011801204600
Center indicator (Upper):indicates whether interruption is present in the top
Center indicator (Middle):
interrupted or not.
Center indicator (Lower):indicates whether interruption is present in the bottom
*The center indicator on the transmitter is OFF when optical synchronization
Center
Light OFFred lightgreen light
light
Top beam axis
Although the top beam axis is
blocked
present in
the GL-R. (clear)
Top beam axis
beam axis is
Although the top and bottom
middle beams are blocked
Bottom beam
User Manual Pdf Download
Although the bottom beam
are blocked
Center
(Upper)
indicator
Center
(Lower)
A
F
32
32.9
38
(only receiver)
Mounting bracketAntivibration bracket
Antivibration bracket for the Adjustable angle
Keyence Gl T11r Pdf
No dead zone mounting bracket
Antivibration bracket for the straight mounting
L-shaped mounting bracketL-shaped mounting bracket
Beam axes
B: Detection heightC: Protection heightD: Beam axis pitch
GL-R08H8160140185
80
GL-R16H16320300345160
GL-R24H24480460505240
GL-R32H32640620665320
GL-R40H40800780825400
GL-R48H48960940985480
GL-R56H56112011001145560
GL-R64H64128012601305640
GL-R80H80160015801625800
GL-R96H96192019001945960
Beam axes
B: Detection heightC: Protection heightD: Beam axis pitch
GL-R04L4160120205
80
GL-R08L8320280365160
Gl T11r Manual
GL-R12L12480440525240
GL-R16L16640600685320
GL-R20L20800760845400
GL-R24L249609201005480
GL-R28L28112010801165560
User Manual